The 4-20mA current loop is a widely used standard in industrial instrumentation for transmitting analog signals from sensors and transmitters to controllers and indicators. It represents a process variable (PV) linearly, where 4mA typically corresponds to the Lower Range Value (LRV) or 0% of the process, and 20mA corresponds to the Upper Range Value (URV) or 100% of the process.
This calculator helps you convert between current (mA), percentage of the process variable (%PV), and the actual process variable value, given the LRV and URV of your instrument's range. This is crucial for calibration, troubleshooting, and understanding process signals.
1. Convert Current (mA) to Process Variable (%) and Value
2. Convert Process Variable (%) to Current (mA) and Value
3. Convert Process Variable Value to Current (mA) and %
Understanding 4-20mA Signals
The 4-20mA current loop is a robust and reliable method for transmitting analog process signals over long distances in industrial environments. Unlike voltage signals, current signals are less susceptible to electrical noise and voltage drops over long cable runs. The use of 4mA as the "live zero" (0% of the process range) is a key safety feature, as a current below 4mA (e.g., 0mA) indicates a broken wire or sensor failure, allowing for immediate fault detection.
Key Concepts:
LRV (Lower Range Value): The minimum value of the process variable that the instrument is configured to measure. This corresponds to 4mA.
URV (Upper Range Value): The maximum value of the process variable that the instrument is configured to measure. This corresponds to 20mA.
Span: The difference between the URV and LRV (URV – LRV). This represents the full measurement range.
Live Zero: The 4mA signal, which indicates 0% of the process range. This allows for differentiation between a true zero reading and a fault condition.
Formulas Used in This Calculator:
Current (mA) to %PV:%PV = ((Current - 4) / 16) * 100
%PV to Current (mA):Current = ((%PV / 100) * 16) + 4
Current (mA) to PV Value:PV Value = LRV + (((Current - 4) / 16) * (URV - LRV))
PV Value to Current (mA):Current = 4 + (((PV Value - LRV) / (URV - LRV)) * 16)
PV Value to %PV:%PV = ((PV Value - LRV) / (URV - LRV)) * 100
%PV to PV Value:PV Value = LRV + ((%PV / 100) * (URV - LRV))
Example Scenarios:
Imagine a pressure transmitter configured for a range of 0 to 100 PSI (LRV=0, URV=100).
If the transmitter outputs 12mA:
Using Section 1: Current (12mA), LRV (0), URV (100) -> Result: 50% PV, 50 PSI.